Produktdetails:
|
Isolierung: | Xlpe | Stromspannung: | 0,6/1kV |
---|---|---|---|
Leitermaterial: | Kupfer | Anwendung: | Über- oder unterirdische Rohrverlegung, Gräbenverlegung, Tunnelverlegung, vertikale Schachten- und B |
No of Core: | 1,2,3,4,5 | Merkmale: | Feuerberechtigung |
Mehradriger XLPE-isolierter Stromkabel Cu-Leiter feuerfestes Kabel mit XLPE-Isolierung EN 60332
Spez. |
Leiterdurchmesser mm |
Ungefährer Außendurchmesser des Kabels mm |
Ungefähres Kabelgewicht kg/km |
||||||
NH |
ZAN |
ZBN |
ZCN |
NH |
ZAN |
ZBN |
ZCN |
||
3×16 |
5.0 |
18.9 |
192 |
192 |
19.2 |
659.4 |
713.1 |
719.2 |
680.1 |
3×25 |
6.1 |
22.5 |
22.5 |
22.5 |
22.5 |
974.7 |
1044.6 |
1051.8 |
996.1 |
3×35 |
72 |
24.8 |
24.8 |
24.8 |
24.8 |
1274.1 |
1361.6 |
1369.6 |
1300.0 |
3×50 |
8.4 |
27.9 |
28.3 |
27.9 |
27.9 |
1659.7 |
1806.0 |
1775.4 |
1692.0 |
3×70 |
10.0 |
32.0 |
32.4 |
32.0 |
32.0 |
2320.7 |
2510.1 |
2474.6 |
2362.4 |
3×95 |
12.0 |
36.4 |
36.9 |
36.4 |
36.4 |
3132.4 |
3375.7 |
3334.7 |
3185.7 |
3×120 |
12.2 |
37.5 |
37.9 |
37.5 |
37.5 |
3797.7 |
4053.5 |
4010.8 |
3853.6 |
3×150 |
13.6 |
41.8 |
41.8 |
41.8 |
41.8 |
4681.2 |
4957.1 |
49455 |
4749.1 |
3×185 |
15.2 |
46.3 |
46.3 |
46.3 |
46.3 |
5813.6 |
6154.0 |
6133.9 |
5896.1 |
3×240 |
17.4 |
51.9 |
51.9 |
51.9 |
51.9 |
7519.6 |
7947.6 |
7923.0 |
7621.7 |
3×300 |
19.5 |
572 |
57.2 |
57.2 |
57.2 |
9355.8 |
9847.1 |
9847.1 |
9478.3 |
3×400 |
22.0 |
64.0 |
64.0 |
64.0 |
64.0 |
11858.3 |
12473.0 |
12473.0 |
12009.4 |
4×1.5 |
1.39 |
12.0 |
12.3 |
12.3 |
12.3 |
186.2 |
201.4 |
201.4 |
201.4 |
4×2.5 |
1.76 |
12.9 |
13.2 |
13.2 |
12.9 |
236.7 |
252.8 |
252.8 |
241.3 |
4×4 |
2.22 |
14.0 |
14.3 |
14.3 |
14.0 |
3092 |
327.2 |
327.2 |
314.2 |
4×6 |
2.74 |
15.3 |
15.6 |
15.6 |
15.3 |
402.2 |
422.6 |
422.6 |
407.8 |
4×10 |
4.0 |
18.3 |
18.6 |
18.6 |
18.6 |
588.5 |
634.7 |
640.6 |
607.4 |
4×16 |
5.0 |
21.0 |
21.0 |
21.0 |
21.0 |
845.5 |
900.0 |
906.7 |
863.1 |
4×25 |
6.1 |
24.7 |
24.7 |
24.7 |
24.7 |
1250.8 |
1328.7 |
1336.6 |
1274.7 |
4×35 |
72 |
27.4 |
27.4 |
27.4 |
27.4 |
1643.6 |
1741.3 |
1750.2 |
1672.6 |
4×50 |
8.4 |
30.9 |
31.4 |
30.9 |
30.9 |
2163.3 |
2326.9 |
2292.5 |
2199.4 |
4×70 |
10.0 |
35.5 |
35.9 |
35.5 |
35.5 |
3031.9 |
3243.8 |
3203.9 |
3078.4 |
4×95 |
12.0 |
40.5 |
41.0 |
40.5 |
40.5 |
4098.6 |
4370.6 |
4324.5 |
4158.1 |
4×120 |
12.2 |
41.8 |
42.3 |
41.8 |
41.8 |
4998.3 |
5285.4 |
5236.4 |
5060.6 |
4×150 |
13.6 |
46.4 |
46.4 |
46.4 |
46.4 |
6136.1 |
6444.3 |
6430.9 |
6211.8 |
4×185 |
15.2 |
51.6 |
51.6 |
51.6 |
51.6 |
7649.6 |
8031.2 |
8006.8 |
7741.8 |
4×240 |
17.4 |
57.8 |
57.8 |
57.8 |
57.8 |
9896.6 |
10376.0 |
10346.5 |
10010.5 |
4×300 |
19.5 |
63.7 |
63.7 |
63.7 |
63.7 |
12314.4 |
12861.8 |
12861.8 |
12451.0 |
4×400 |
22.0 |
71.3 |
71.3 |
71.3 |
71.3 |
15606.1 |
16291.7 |
16291.7 |
15774.6 |
5×1.5 |
1.39 |
13.0 |
13.3 |
13.3 |
13.3 |
218.6 |
235.5 |
235.5 |
235.5 |
5×2.5 |
1.76 |
14.0 |
14.3 |
14.3 |
14.0 |
280.8 |
298.8 |
299.5 |
285.8 |
5×4 |
2.22 |
152 |
15.5 |
15.5 |
15.2 |
369.9 |
391.0 |
391.0 |
375.4 |
5×6 |
2.74 |
16.6 |
16.9 |
16.9 |
16.6 |
484.6 |
508.5 |
508.5 |
490.7 |
5×10 |
4.0 |
20.4 |
20.4 |
20.4 |
20.4 |
7192 |
769.4 |
776.9 |
7356 |
5×16 |
5.0 |
23.1 |
23.1 |
23.1 |
23.1 |
1031.4 |
1097.7 |
1106.4 |
1052.2 |
5×25 |
6.1 |
27.2 |
27.2 |
27.2 |
27.2 |
1533.7 |
1628.8 |
1637.6 |
1562.1 |
5×35 |
72 |
30.1 |
30.1 |
30.1 |
30.1 |
2021.3 |
2140.4 |
2150.2 |
2055.8 |
5×50 |
8.4 |
34.2 |
34.7 |
34.2 |
34.2 |
2680.5 |
2876.9 |
2838.3 |
2723.7 |
5×70 |
10.0 |
39.3 |
39.8 |
39.3 |
39.3 |
3760.0 |
4014.9 |
3970.1 |
3815.8 |
5×95 |
12.0 |
45.1 |
45.5 |
45.1 |
45.1 |
5107.2 |
5436.4 |
5383.7 |
5178.7 |
5×120 |
12.2 |
46.3 |
46.7 |
46.3 |
46.3 |
6204.7 |
6550.6 |
6495.8 |
6279.6 |
5×150 |
13.6 |
51.6 |
51.6 |
51.6 |
51.6 |
7643.2 |
8020.9 |
8004.6 |
7734.5 |
5×185 |
15.2 |
57.4 |
57.4 |
57.4 |
57.4 |
9525.2 |
9992.5 |
9963.3 |
9636.4 |
5×240 |
17.4 |
64.2 |
64.2 |
64.2 |
64.2 |
12322.0 |
12909.5 |
12874.3 |
12459.9 |
Kontaktieren Sie uns für weitere Details
Q. Was ist die maximale Betriebstemperatur von mehradrigen XLPE-isolierten Kupferleiter-Brandschutzkabeln?
A. Die Dauerbetriebstemperatur beträgt typischerweise 90°C (konform mit IEC 60502-2) mit Kurzschlussfestigkeit bis zu 250°C für 5 Sekunden
Q. Welchen Brandschutznormen entsprechen diese Kabel?
A. Sie erfüllen IEC 60332-3-22 (Flammenausbreitung in vertikalen Installationen) und IEC 60331 (Feuerwiderstandsdauer, z. B. 90 Minuten bei 750 °C)
Q.Wo werden diese Kabel üblicherweise installiert?
A. Kritische Anwendungen umfassen Hochhäuser (Notstromkreise), U-Bahn-Tunnel (Raucharmutsanforderungen) und Kraftwerke (Bereiche mit hoher mechanischer Beanspruchung)
Q. Was ist der Unterschied zwischen flammhemmenden und feuerbeständigen Versionen?
A. Flammhemmende Kabel verlangsamen die Flammenausbreitung (IEC 60332-1), während feuerbeständige Kabel die Schaltungsintegrität aufrechterhalten während Bränden (IEC 60331)
Q. Können diese Kabel in unterirdischen oder marinen Umgebungen verwendet werden?
A. Ja, mit Stahldrahtarmierung (SWA) für die unterirdische Verlegung (IEC 60502-2) oder halogenfreien Mänteln für die Korrosionsbeständigkeit im maritimen Bereich
Q. Welche Leitermaterialien sind außer Kupfer verfügbar?
A. Aluminiumkernvarianten existieren (z. B. AAAC-Leiter), bieten aber geringere Leitfähigkeit (≈61 % von Kupfer) und höheres Gewicht
Q. Wie viele Adern können diese Kabel haben?
A. Standardkonfigurationen umfassen 1-5 Adern (Einphasen- bis Dreiphasensysteme), mit Optionen für konzentrische Erdungsleiter
Q.Benötigen diese Kabel besondere Installationsvorkehrungen?
A. Vermeiden Sie scharfes Biegen (Mindestbiegeradius: 12 × Kabeldurchmesser) und Überhitzung während des Schweißens in der Nähe von PVC-Mänteln