Szczegóły Produktu:
|
Stosowanie: | System kontroli dostępu | Izolacja: | XLPE PE PVC |
---|---|---|---|
Woltaż: | 0,6/1KV | Długość: | dostosowane |
Materiał przewodnika: | Miedź | Uszczelka: | Neutralne pakowanie kartonu lub dostosowane |
EAC Certified Fire Resistant Cable N2XH LSZH Environmental Protection Cable
Conductor: Typically composed of high-purity copper or aluminum, annealed for flexibility and low resistance.
Insulation: Cross-linked polyethylene (XLPE) insulation provides excellent thermal resistance (up to 90°C) and dielectric strength.
Shielding: A concentric copper tape or braid shield minimizes electromagnetic interference (EMI).
Jacket: Thermoplastic or thermosetting material (e.g., PVC or LSZH) offers abrasion resistance and flame retardancy.
Dimensions- Number of cores X cross-section |
Design | Construction of the individual keep the handlers safe |
The outer diameter |
thickness of insulation |
shell thickness |
Resistance to keep the handlers safe at 20°C |
Weight Cu | weight of cable |
rated | about | rated | rated | max. | about | |||
Nx mm² | nx mm | mm | mm | mm | Q/km | kg/km | kg/km | |
1×1,5 | RE | 1×1,38 | 54 | 138 | 15 | 1,210 | 15,403 | 43 |
1×4 | RE | 1×2,25 | 64 | 225 | 20 | 461 | 5,869 | 75 |
1×16 | RM | 7×1,70 | 91 | 500 | 36 | 115 | 1,464 | 202 |
1×25 | RM | 7×2,13 | 11 | 610 | 48 | 727 | 925 | 302 |
1×70 | RM | 19×2,17 | 15 | 1,010 | 84 | 268 | 341 | 745 |
1×95 | RM | 19×2,52 | 17 | 1,190 | 97 | 193 | 246 | 986 |
1×185 | RM | 37×2,52 | 23 | 1,620 | 172 | 991 | 126 | 1888 |
1×300 | RM | 61x2,50 | 28 | 2,060 | 234 | 601 | 77 | 2945 |
2×1,5 | RE | 1×1,38 | 9 | 138 | 38 | 1,210 | 15,403 | 120 |
2×2,5 | RE | 1×1,78 | 10 | 178 | 45 | 741 | 9,433 | 154 |
2×16 | RM | 7×1,70 | 16 | 500 | 106 | 115 | 1,464 | 563 |
2×25 | RM | 7×2,13 | 20 | 610 | 152 | 727 | 925 | 840 |
2×35 | RM | 7×2,52 | 22 | 720 | 179 | 524 | 667 | 1106 |
2×120 | RM | 37×2,03 | 36 | 1,300 | 423 | 153 | 195 | 3343 |
2x300 | RM | 61x2,50 | 55 | 2,060 | 939 | 601 | 77 | 8072 |
3×1,5 | RE | 1×1,38 | 9 | 138 | 44 | 1,210 | 15,403 | 135 |
3×2,5 | RE | 1×1,78 | 10 | 178 | 51 | 741 | 9,433 | 181 |
3×4 | RE | 1×2,25 | 11 | 225 | 60 | 461 | 5,869 | 242 |
3×10 | RE | 1×3,56 | 14 | 357 | 83 | 183 | 2,330 | 464 |
3×16 | RM | 7×1,70 | 17 | 500 | 122 | 115 | 1,464 | 697 |
N2XH | ||||||||
3×35 | RM | 7×2,52 | 23 | 720 | 208 | 524 | 667 | 1393 |
3×50 | RM | 19×1,83 | 26 | 830 | 256 | 387 | 493 | 1847 |
3×70 | RM | 19×2,17 | 31 | 1,010 | 343 | 268 | 341 | 2666 |
3×95 | RM | 19×2,52 | 36 | 1,190 | 417 | 193 | 246 | 3535 |
3×120 | RM | 37x2,03 | 38 | 1,300 | 474 | 153 | 195 | 4322 |
3×185 | RM | 37x2,52 | 48 | 1,620 | 740 | 991 | 126 | 6742 |
3×300 | RM | 61×2,50 | 59 | 2,060 | 1,079 | 601 | 77 | 10522 |
1. What is N2XH cable?
N2XH is a European standard (EN) halogen-free flame-retardant power cable, where "N" denotes non-spreading flame and "XH" indicates cross-linked polyethylene (XLPE) insulation. The J/O suffixes differentiate between rigid (Class 1) and flexible (Class 5) conductor versions.
2. Typical applications?
Public buildings (hospitals, hotels)
Industrial plants (chemical/oil facilities)
Transport systems (metro, railways)
3. Voltage rating & temperature range?
Rated voltage: 0.6/1kV
Operating temp: -40°C to +90°C (fixed installation)
Short-circuit withstand: +250°C (5 sec max)
4. Installation precautions?
Minimum bending radius: 12× cable diameter
Avoid parallel routing with high-voltage cables (keep ≥300mm spacing)
Use proper glanding tools for shield termination
5. Advantage over PVC cables?
50% lower smoke density in fires (IEC 61034 test)
No corrosive halogen gases (IEC 60754-1 compliant)
6. Maintenance recommendations?
Annual insulation resistance test (>20MΩ·km)
Visual inspection for sheath damage in corrosive environments
Osoba kontaktowa: Mr. Bai
Tel: +8619829885532