Подробная информация о продукте:
|
Изоляция: | Xlpe | Напряжение: | 0,6/1 кВ |
---|---|---|---|
Материал дирижера: | Медь | Приложение: | Наземное или подземное прокладка труб, траншей, туннелей, вертикальных валов и мостов |
Нет ядра: | 1,2,3,4,5 | Функции: | Огневой режим |
MV Medium Voltage XLPE Insulated Power Cable Three Core Copper Tape Shield EN60502
Specs |
Conductor diameter |
Nominal thickness of insulation |
Outside diameter of insulation |
Nominal thickness of sheath |
Approximate outer diameter of cable |
Approximate cable weight |
3×25 |
6.0 |
4.5 |
17.0 |
2.4 |
47.0 |
2274 |
3×35 |
7.0 |
4.5 |
18.0 |
2.5 |
49.5 |
2673 |
3×50 |
8.2 |
4.5 |
19.2 |
2.6 |
52.3 |
3156 |
3×70 |
10.0 |
4.5 |
20.8 |
2.7 |
55.9 |
3932 |
3×95 |
11.6 |
4.5 |
22.6 |
2.8 |
60.0 |
4879 |
3×120 |
13.0 |
4.5 |
24.0 |
2.9 |
63.2 |
5743 |
3×150 |
14.4 |
4.5 |
25.4 |
3.0 |
66.5 |
6700 |
3×185 |
16.1 |
4.5 |
27.2 |
3.1 |
70.6 |
7919 |
3×240 |
18.4 |
4.5 |
29.4 |
3.3 |
75.7 |
9782 |
3×300 |
20.6 |
4.5 |
31.6 |
3.4 |
80.7 |
11755 |
3×400 |
23.4 |
4.5 |
34.4 |
3.7 |
87.4 |
14550 |
3×500 |
26.6 |
4.5 |
38.5 |
3.8 |
97.3 |
18348 |
3×630 |
30.0 |
4.5 |
41.9 |
4.1 |
105.3 |
22765 |
Contact us for more details
Q: Why is copper tape shielding used in this cable?
A: The copper tape shield (CTS) provides electromagnetic interference (EMI) protection and ensures low impedance, maintaining signal integrity in sensitive industrial environments.
Q: What are the advantages of XLPE insulation?
A: XLPE offers high dielectric strength (up to 90°C), thermal stability, and resistance to moisture/chemicals, outperforming traditional PVC insulation.
Q: What conductor sizes are available?
A: Standard cross-sections range from 25mm² to 630mm², with 3-core configurations (e.g., 3x240mm²) for balanced phase current distribution.
Q:Is this cable suitable for underground installations?
A: Yes, it features steel wire/tape armoring (SWA/STA) for mechanical protection and is rated for direct burial or ducting, complying with IEC60502 standards.
Q: Are there flame-retardant options?
A: Yes, variants like LSZH (low-smoke zero-halogen) sheath are available for fire-prone areas such as tunnels and high-rises.
Q: What bending radius is required during installation?
A: Minimum bending radius is 12× overall diameter for 3-core cables (15× for single-core), ensuring insulation integrity.
Q: Which international standards does this cable comply with?
A:It meets IEC60502-2, VDE0276, and BS7835 for performance, safety, and environmental resistance
Контактное лицо: Mr. Bai
Телефон: +8619829885532