Product Details:
|
Application: | Construction | Sheath: | Rubber |
---|---|---|---|
Insulation Options: | PVC, Rubber, Or EPR | Metric Cross-Sections: | 10mm² To 240mm² |
Conductor Material: | Copper | Color: | Black, Orange, Red, Etc. |
Z and YZW medium-duty rubber-sheathed flexible cables are widely used in various mobile electrical equipment and tools with an AC rated voltage of 300/500V. Their primary applications include:
Conductor:Class 5 flexible copper
Insulation :EPR (Ethylene Propylene Rubber) Type EI4 compound
Sheath : PCP (Neoprene/ Polychloroprene) Type EM2 compound
Cores× |
Conductive |
Average Outer Dia(mm²) |
20℃ Conductor |
Reference Weight(kg/km) |
|||
Number/Diameter |
Minimum |
Maximum Limit |
Copper core |
Tinning Copper |
YQ |
YQW |
|
2×0.75 |
24×0.20 |
6.0 |
8.2 |
26.0 |
26.7 |
|
|
2×1 |
32×0.20 |
6.4 |
8.8 |
19.5 |
20.0 |
81.7 |
89.6 |
2×1.5 |
30×0.25 |
8.0 |
10.5 |
13.3 |
13.7 |
|
|
2×2.5 |
49×0.25 |
9.4 |
12.5 |
7.98 |
8.21 |
227.1 |
242.6 |
2×4 |
56×0.30 |
11.0 |
14.0 |
5.0 |
5.09 |
|
|
2×6 |
84×0.30 |
12.5 |
17.0 |
3.3 |
3.39 |
366.0 |
394.5 |
3×0.75 |
24×0.20 |
6.6 |
8.8 |
26.0 |
26.7 |
|
|
3×1 |
32×0.20 |
6.8 |
9.2 |
19.5 |
20.0 |
97.4 |
105.0 |
3×1.5 |
30×0.25 |
8.4 |
11.0 |
13.3 |
13.7 |
|
|
3×2.5 |
49×0.25 |
10.0 |
13.0 |
8.0 |
8.21 |
205.1 |
219.2 |
3×4 |
56×0.30 |
11.5 |
14.5 |
5.0 |
50.9 |
|
|
3×6 |
84×0.30 |
13.0 |
18.0 |
3.3 |
3.39 |
452.5 |
497.7 |
4×0.75 |
24×0.20 |
7.2 |
9.6 |
26.0 |
26.7 |
|
|
4×1 |
32×0.20 |
7.6 |
10.0 |
19.5 |
20.0 |
117.1 |
125.2 |
4×1.5 |
30×0.25 |
9.4 |
12.5 |
13.3 |
13.7 |
|
|
4×2.5 |
49×0.25 |
11.0 |
14.0 |
8.0 |
8.21 |
255.2 |
270.9 |
4×4 |
56×0.30 |
13.0 |
16.5 |
5.0 |
5.09 |
|
|
4×6 |
84×0.30 |
14.5 |
20.0 |
3.3 |
3.39 |
564.0 |
594.0 |
3×1.5+1×10 |
30/0.25+32/0.20 |
9.4 |
12.0 |
13.3 |
13.7 |
170.1 |
181.9 |
3×2.5+1×1.5 |
49/0.25+30/0.25 |
11.0 |
14.0 |
8.0 |
8.21 |
246.8 |
262.9 |
3×4+1×2.5 |
56/0.30+49/0.25 |
13.0 |
16.0 |
5.0 |
5.09 |
359.1 |
380.2 |
3×6+1×4 |
84/0.30+56/0.30 |
14.5 |
19.5 |
3.3 |
3.39 |
542.1 |
572.5 |
5×0.75 |
24/0.20 |
8.0 |
11.0 |
26.0 |
26.7 |
127.1 |
136.8 |
5×1 |
32/0.20 |
8.4 |
11.5 |
19.5 |
20.0 |
144.3 |
154.5 |
5×1.5 |
30/0.25 |
10.0 |
13.5 |
13.3 |
13.7 |
210.5 |
223.6 |
5×2.5 |
49/0.25 |
12.5 |
15.5 |
8.0 |
8.21 |
304.3 |
322.4 |
5×4 |
56/0.30 |
14.5 |
18.0 |
5.0 |
5.09 |
441.8 |
464.5 |
5×6 |
84/0.30 |
16.5 |
22.5 |
3.3 |
3.39 |
687.5 |
724.0 |
Q: What is the main difference between YZ and YZW cables?
A: YZW cables feature weather-resistant and oil-resistant properties due to their special rubber compounds, making them suitable for outdoor or oily environments, while standard YZ cables are designed for general indoor/outdoor use
Q: What is the maximum operating temperature for YZ/YZW cables?
A: The conductor's maximum continuous operating temperature is 65°C, with ambient temperature ranging from -20°C to +45°C.
Q: Are these cables suitable for agricultural applications?
A: Yes, they are widely used in agricultural electrification for mobile power supply of machinery and equipment.
Q: Can YZW cables be exposed to sunlight and oil?
A: Yes, their chloroprene or equivalent synthetic elastomer sheaths provide excellent UV and oil resistance.
Q: Do these cables support high mechanical stress?
A: As medium-duty cables, they withstand moderate mechanical forces but are less robust than heavy-duty YC/YCW models.
Q: Are flame-retardant variants available?
A: Yes, ZR-type cables with flame-retardant properties can be customized upon request.
Q: What conductor materials are used?
A: Class 5 flexible copper conductors, optionally tinned for corrosion resistance.
Q: What voltage tests are performed on these cables?
A: They undergo a 2.0kV/5min dielectric strength test to ensure insulation integrity.
Contact Person: Mr. Bai
Tel: +8619829885532