Product Details:
|
Insulation Material: | Xlpe | Jacket: | PE |
---|---|---|---|
Conductor Material: | Stranded Circular Or Segmental (Milliken) Compacted Copper Conductor | Nominal Voltage: | 38/66kV(72.5kV) |
Core: | 1 Core | Application: | Underground |
IEC 60840 IEC 62067
Conductor |
Insulation |
Nominal Area of Copper Wires |
Outer Jacket |
||||||||||||
Nominal |
Max.DC |
Max.AC |
Nominal Thickness of Insulation |
Nominal |
Approx. |
Approx. |
|||||||||
Cond. |
XLPE |
Ins. |
|||||||||||||
mm² |
Ω/km |
Ω/km |
mm |
mm |
mm |
mm² |
mm |
mm |
kg/m |
||||||
300 R |
0.0601 |
0.0787 |
1.2 |
15 |
1 |
95 |
3.5 |
67.9 |
6.47 |
||||||
400 R |
0.047 |
0.0627 |
1.2 |
15 |
1 |
95 |
3.5 |
70.5 |
7.41 |
||||||
500 R |
0.0366 |
0.0502 |
1.2 |
15 |
1 |
95 |
4 |
74.9 |
8.79 |
||||||
630 R |
0.0283 |
0.0407 |
1.2 |
15 |
1 |
95 |
4 |
78.4 |
10.21 |
||||||
800 R |
0.0221 |
0.0338 |
1.2 |
15 |
1 |
95 |
4 |
82.4 |
12.17 |
||||||
1000 S |
0.0176 |
0.024 |
1.5 |
15 |
1.2 |
95 |
4 |
92.1 |
14.74 |
||||||
1200 S |
0.0151 |
0.0211 |
1.5 |
15 |
1.2 |
95 |
4.5 |
97.1 |
17 |
||||||
1400 S |
0.0129 |
0.0185 |
1.5 |
15 |
1.2 |
95 |
4.5 |
99.1 |
18.99 |
||||||
1600 S |
0.0113 |
0.0168 |
1.5 |
15 |
1.2 |
95 |
4.5 |
103.1 |
20.72 |
||||||
2000 S |
0.009 |
0.0143 |
1.5 |
15 |
1.2 |
95 |
4.5 |
108.1 |
24.42 |
||||||
2500 S |
0.0072 |
0.0125 |
1.5 |
15 |
1.2 |
95 |
4.5 |
116.1 |
29.99 |
Q.What does "FL" signify in the cable model?
A."FL" indicates longitudinal water-blocking (F) and termite-proof (L) features, suitable for humid or pest-prone environments
Q.What materials are used for conductor and insulation?
A.2XS(FL)2Y: Copper conductor (Cu) with XLPE insulation.
A2XS(FL)2Y: Aluminum conductor (Al) with XLPE insulation.
Q.What is the shielding structure of these cables?
A. Copper wire screen (S) and longitudinal water-blocking tape for EMI protection and moisture resistance
Q.Where are these cables typically installed?
A.Used in urban grids, industrial plants, and underground networks due to their durable armor (e.g., PVC sheath)
Q. What temperature range can these cables withstand?
A. Operating temperature: -20°C to +90°C (XLPE insulation ensures thermal stability)
Q.Are these cables flame-retardant?
A. Yes, variants with LSZH (low-smoke zero-halogen) sheaths are available for fire safety
Q.How to distinguish between 2XS(FL)2Y and A2XS(FL)2Y?
A."A" prefix denotes aluminum conductor, while the copper variant omits it
Q.What is the lifespan of these cables?
A. Designed for 30+ years with proper installation, supported by 10-year quality guarantees from manufacturer
Contact Person: Mr. Bai
Tel: +8619829885532