logo
Главная страница ПродукцияXLPE изолировало силовой кабель

EAC Certificated XLPE Insulated 8.7kV 15kV 25mm2-800mm2 Flame-retardant Power Cable

EAC Certificated XLPE Insulated 8.7kV 15kV 25mm2-800mm2 Flame-retardant Power Cable

EAC Certificated XLPE Insulated 8.7kV 15kV 25mm2-800mm2 Flame-retardant Power Cable
EAC Certificated XLPE Insulated 8.7kV 15kV 25mm2-800mm2 Flame-retardant Power Cable EAC Certificated XLPE Insulated 8.7kV 15kV 25mm2-800mm2 Flame-retardant Power Cable EAC Certificated XLPE Insulated 8.7kV 15kV 25mm2-800mm2 Flame-retardant Power Cable EAC Certificated XLPE Insulated 8.7kV 15kV 25mm2-800mm2 Flame-retardant Power Cable

Большие изображения :  EAC Certificated XLPE Insulated 8.7kV 15kV 25mm2-800mm2 Flame-retardant Power Cable

Подробная информация о продукте:
Место происхождения: Хэбэй, Китай
Фирменное наименование: Zhongdong
Сертификация: ISO9001, CE, CCC, RoHS, VDE, cUL, CSA
Оплата и доставка Условия:
Количество мин заказа: быть согласованным
Цена: To be negotiated
Упаковывая детали: Рулоны, деревянные барабаны, стальные барабаны, катушки или индивидуальные
Время доставки: 7-30 дней на основе различных QUTY
Условия оплаты: , L/C, T/T.
Поставка способности: 100 км в неделю

EAC Certificated XLPE Insulated 8.7kV 15kV 25mm2-800mm2 Flame-retardant Power Cable

описание
Изоляция: Xlpe Напряжение: 0,6/1 кВ
Материал дирижера: Медь Приложение: Наземное или подземное прокладка труб, траншей, туннелей, вертикальных валов и мостов
Нет ядра: 1,2,3,4,5 Функции: Огневой режим

EAC Certificated XLPE Insulated 8.7kV 15kV 25mm2-800mm2 Flame-retardant Power Cable



APPLICATION

Suitable for power supply lines with flame retardant requirements, such as urban underground power grids, power station outgoing lines, and internal power lines of industrial and mining enterprises.




CONSTRUCTION


  • Conductor: Tightly press circular conductor 
  • Conductor shield: Semi conductive shielding material (below 500mm ²) Semi conductive tape+semi conductive shielding material (500mm ² and above) 
  • Insulation: XLPE 
  • Insulation shielding: Peelable semiconducting shielding material 
  • Metal shielding layer: Copper Tape   Copper wire (35kV, 500m ² and above) 
  • Filler: Non hygroscopic filling rope 
  • Binder Tape: Non hygroscopic straps 
  • Armor:  1 core: stainless steel tape    3 core: galvanized steel tape 
  • Inner and outer sheaths:  90 ℃ flame retardant polyvinyl chloride 




EAC Certificated XLPE Insulated 8.7kV 15kV 25mm2-800mm2 Flame-retardant Power Cable 0EAC Certificated XLPE Insulated 8.7kV 15kV 25mm2-800mm2 Flame-retardant Power Cable 1EAC Certificated XLPE Insulated 8.7kV 15kV 25mm2-800mm2 Flame-retardant Power Cable 2EAC Certificated XLPE Insulated 8.7kV 15kV 25mm2-800mm2 Flame-retardant Power Cable 3



CHARACTERISTICS


  • Voltage Rating Uo/U: 8.7/10(12)kV,8.7/15(17.5)kV
  • Maximum operating temperature of conductor:+90℃
  • Operating ambient temperature: -15℃~+55℃
  • Cable laying temperature:Not less than 0℃(When the ambient temperature is below 0℃, the cable should be preheated.) 
  • Minimum Bending Radius: Single core:15D  Three Core: 12D (D is the actual outer diameter of the cable)




SPECIFICATIONS



Specs mm²

Conductor diameter              mm

Nominal  thickness of insulation ±1.0mm

Approx outer diameter of cable         mm

Approx cable weight  kg/km

 

Specs mm²

Conductor diameter mm

Nominal  thickness of insulation ±1.0mm

Approx outer diameter of cable

mm

Approx cable weight kg/km

1×25

5.6±0.1

17.2

24.1

926

 

3×25

5.6±0.1

17.2

47.3

3168

1×35

6.6±0.2

18.2

25.3

1065

3×35

6.6±0.2

18.2

49.7

3609

1×50

7.6±0.2

19.2

26.3

1215

3×50

7.6±0.2

19.2

52.2

4152

1×70

9.2±0.2

20.8

28.0

1478

3×70

9.2±0.2

20.8

55.8

4988

1×95

10.9±0.2

22.5

29.7

1781

3×95

10.9±0.2

22.5

60.0

6051

1×120

12.2±0.2

23.8

31.2

2066

3×120

12.2±0.2

23.8

63.1

6976

1×150

13.6±0.2

25.2

32.6

2370

3×150

13.6±0.2

25.2

66.3

8038

1×185

15.2±0.2

26.8

35.7

3105

3×185

15.2±0.2

26.8

70.1

9343

1×240

17.4±0.2

29.0

38.0

3744

3×240

17.4±0.2

29.0

75.4

11343

1×300

19.5±0.2

31.1

40.3

4412

3×300

19.5±0.2

31.1

81.6

14262

1×400

22.0±0.2

33.6

43.2

5297

3×400

22.0±0.2

33.6

87.5

17106

1×500

24.8±0.2

37.2

47.1

6520

 

3×500

24.8±0.2

37.2

95.8

21121

1×630

28.2±0.2

40.6

50.7

7997

 

3×630

28.2±0.2

40.6

104.0

25921

1×800

33.7±0.2

46.1

56.5

10048

 

 

 

 

 





Contact us for more details



OUR FACTORY


EAC Certificated XLPE Insulated 8.7kV 15kV 25mm2-800mm2 Flame-retardant Power Cable 4


PROJECTS


EAC Certificated XLPE Insulated 8.7kV 15kV 25mm2-800mm2 Flame-retardant Power Cable 5

PARTNERS


EAC Certificated XLPE Insulated 8.7kV 15kV 25mm2-800mm2 Flame-retardant Power Cable 6EAC Certificated XLPE Insulated 8.7kV 15kV 25mm2-800mm2 Flame-retardant Power Cable 7


WHY US


EAC Certificated XLPE Insulated 8.7kV 15kV 25mm2-800mm2 Flame-retardant Power Cable 8



FAQ

Q: What does EAC certification mean for these cables?
A: EAC certification confirms compliance with Eurasian Economic Union (EAEU) technical regulations, ensuring the cables meet safety and performance standards for member countries (Russia, Kazakhstan, etc.).
Q. Why are these cables flame-retardant?
A: Flame-retardant additives in the insulation and jacket materials prevent rapid flame spread in case of fire, meeting IEC 60332-1/2 standards.
Q:. What applications suit 8.7kV vs 15kV cables?
A:  8.7kV: Industrial plants, medium-range power distribution; 15kV: Urban grids, high-load substation connections
Q. How does conductor size (25-800mm²) affect performance?
A: Larger cross-sections (e.g., 800mm²) reduce resistance, enabling higher current capacity (up to 1,000A) for long-distance transmission.
Q: Are these cables suitable for underground installation?
A: Yes, when equipped with armored layers (e.g., steel wire armor), they resist mechanical damage and moisture in underground ducts.
Q. What bending radius is recommended during installation?
A: Minimum bending radius is 12× cable diameter for unarmored and 15× for armored versions to avoid insulation stress.
Q. Do these cables require special maintenance?
A: No, XLPE insulation is moisture-resistant and requires only periodic thermal inspections via infrared scanning.
Q. What documentation is needed for EAC customs clearance?
• EAC certificate of conformity
• Test reports (voltage withstand, flame retardancy)
• Technical passport with HS code 8544.49.10


Контактная информация
Zhongdong Cable Co., Ltd.

Контактное лицо: Mr. Bai

Телефон: +8619829885532

Оставьте вашу заявку (0 / 3000)

Другие продукты